Part Number Hot Search : 
00380 BU7233SF QC962 2N6075A AMC7584 E18CA 4732A RBV1000
Product Description
Full Text Search
 

To Download MU25APS20 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  www.imopc.com trips out the unit as voltage is applied. mounting inside the unit. voltage product 24 ac mu25a a24 110 ac mu25a a110 220-240 ac mu25a a240 380-415 ac mu25a a400 for fitting to the side of the unit max 1 block each side. contacts product 1 make + 1 break mu25a pe11 (internal mount) 1 break mu25a ps01 1 make + 1 break mu25a ps11 2 makes mu25a ps20 2 early makes mu25a pv20 manual motor starter mu ? overload protection ? short circuit protection ? phase differential detection ? din rail mounting ? test facility ? ambient temperature compensation ? fingertouch protection ? lockable off position ? designed to en60947-4-1 and en60947-2 ? bus-bar system ? enclosures mu/03/03 current range magnetic short product amps circuit trip-amps 0.10 - 0.16 1.92 mu25a 0.16 0.16 - 0.25 3.0 mu25a 0.25 0.25 - 0.40 4.8 mu25a 0.40 0.40 - 0.63 7.6 mu25a 0.63 0.63 - 1.00 12.0 mu25a 1.00 1.00 - 1.60 19.2 mu25a 1.60 1.60 - 2.50 30 mu25a 2.50 2.50 - 4.00 48 mu25a 4.00 4.00 - 6.30 75.6 mu25a 6.30 6.30 - 10 120 mu25a 10 10 - 16 192 mu25a 16 16 - 20 240 mu25a 20 20 - 25 300 mu25a 25 options and ordering codes accessories auxiliary contacts shunt trip specification rated insulation voltage ui 690v ac rated current ith open, at 50?c 25 amps mechanical life 100,000 ops electrical life ?ac3 duty 100,000 ops switching frequency 30 ops per hour operate time ?approximately 7 ms total power loss (warm condition) 6-8 w temperature compensation open ?0 to +55?c rating auxiliary switch ?ac15 400v 2a mounting position any power consumption ?undervoltage trip 2.7va 1.8w ?shunt trip 2.7va 1.8w terminal wiring cross section 1 or 2 wires main 0.75 ?4mm2 aux 0.75 ?2.5mm2 weight 0.25 kg
www.imopc.com accepts contactor and manual motor starter to mount onto one din rail. product mbs25 pl54 for increasing the fault breaking capacity of single unit or group back-up to 50ka. u i = 690v i u = 32a product mbs25 id50 system for connecting units together and incoming supply. fully isolated ui = 690v i u = 63 amps description product for 2 units - 99mm mbs25 d99 for 3 units - 154mm mbs25 d154 for 4 units - 208mm mbs25 d208 for 5 units - 262mm mbs25 d262 protection for unused terminals mbs25 bs supply block mbs25 db spacing piece 1 / 2 te p730 trips out the unit should the voltage fall below 70% of the rated voltage, prevents automatic restart when voltage returns. for mounting inside the unit. voltage product 220-240 ac mu25a u230 380-415 ac mu25a u400 24 ac mu25a u24 110 ac mu25a u110 manual motor starter mu continued mu/03/03 accessories continued undervoltage trip bus-bar system current limiter starter carrier description product moulded enclosure - ip55 mu25a o55 moulded front plate - ip55 mu25a c55 locking bracket - 3 position mu25a z mushroom stop button mu25a nat green indicator 240v mu25a sg230 red indicator 240v mu25a sr230 earth or neutral conductor mu25a nl moulded enclosure cee socket mu25a gc1 enclosures current range rated short circuit capacity ka back-up fuse (gi) 220-240 380-415 500 660-690 220-240 380-415 500 660-690 0.10 - 0.16 100 100 100 100 0.16 - 0.25 100 100 100 100 0.25 - 0.40 100 100 100 100 0.40 - 0.63 100 100 100 100 0.63 - 1.00 100 100 100 100 1.00 - 1.60 100 100 100 100 1.60 - 2.50 100 100 3 2.5 25 25 2.50 - 4.00 100 100 3 2.5 35 25 4.00 - 6.30 100 100 3 2.5 50 35 6.30 - 10 100 6/50* 32.5 80 50 35 10 -16 10/100* 4/50* 2.5 2 80 80 63 35 16 - 20 10/100* 4/50* 2.5 2 80 80 63 50 20 - 25 10/100* 4/50* 2.5 2 80 80 63 50 electrical characteristics *ka with current limiter mbs25-id50 up to 415v ac fuse not required trip curve x setting current average value of typical tolerance curves from cold condition trip curve 1. three phase trip curve
www.imopc.com manual motor starter mu continued mu/03/03 dimensions (mm) manual motor starter mu25a moulded enclosure mu25a-o55 moulded enclosure for 5-pole cee-plug mu25a-gc1 moulded front plate mu25a-c55 rail according to din en 50 022 76 43 23 72 82 45 9 30 m4 80 38 20 55 ?.5 97.5 4 x pg16 90 140 m4 68 54.5 6 8 130 145 199 85 max. 6 80 14 70-72 r4-6 45 33-34 64 m4 70-72 mounting with clamps with screws 116-118 116-118 110 129 105 ?1 42.5 85 103 aux. contact 80 45 76.5 150


▲Up To Search▲   

 
Price & Availability of MU25APS20

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X